  • Can the ACE-1748 (ACE-1768) be controlled from NI LabVIEW?
  • How can I set the connection through the Internet to AAE-2712 which is connected to the router local network with private static IP address?
  • Can I commutate several inputs to one output simultaneously when working with AEE-2025 and AEE-2085?

  • Can the ACE-1748 (ACE-1768) be controlled from NI LabVIEW?
    Yes, it can be. The complete SDK (ACE-17x8_SDK) includes tools and an example for NI LabVIEW. The ready-made palette VI ACE-1768 contains tools for connecting to the device via USB and LAN, reading the status of inputs and outputs, and for controlling outputs. The included sample application demonstrates their use. You can also build the required virtual instrument yourself by calling the ACE1768.dll library functions using the built-in LabVIEW Call Library Function Node. - Yes, it can be.
    The complete SDK (ACE-17x8_SDK) includes tools and an example for LabVIEW. The ready-made palette VI ACE-1768 contains tools for connecting to the device via USB and LAN, reading the status of inputs and outputs, and for controlling outputs. The included sample application demonstrates their use.
    You can also build the required virtual instrument yourself by calling the ACE1768.dll library functions using the built-in LabVIEW Call Library Function Node.

    Up

    How can I set the connection through the Internet to AAE-2712 which is connected to the router local network with private static IP address?

    For the Internet connection Aktakom AAE-2712 requires to set the port forwarding on your router from the router external address to the device internal address in the local network. That means to open the port for the access from the Internet (e.g. 190.10.80.103:8080 where 190.10.80.103 is your private static IP address, 8080 is the port number) and assign/forward IP address and the port in the local network to it (e.g. 192.168.1.110:1024, where 192.168.1.110 is your local network IP address assigned/forwarded to AAE-2712 and 1024 is the port number).

    To connect to the device through the local network it’s necessary to specify the local IP address and the port of the device in the software settings (e.g. 192.168.1.110:1024). And to connect to the device through the Internet you will have to specify your private static IP address and the port (e.g. 190.10.80.103:8080).


    Up

    Can I commutate several inputs to one output simultaneously when working with AEE-2025 and AEE-2085?

    Yes, you can. AEE-2025 (and AEE-2085) allows you to commutate any number of input lines to any number of output lines. At the same time you may at will specify any constraints in the program for commutation variants. It’s convenient to use such software constraints if you need to commutate independent signals with the help of one commutator.