AKTAKOM AM-1060 handheld digital multimeter is designed to offer all the features needed to help you obtain accurate measurements and quickly detect problems in electronics troubleshooting.
AM-1060 handheld digital multimeter (analog of Lutron DM-9960) provides multi function measurement: DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Temperature, Diode, Continuity beeper. AKTAKOM AM-1060 digital multimeter combines wide range, high accuracy and safety.
Large LCD and bar graph make this multimeter especially useful in education: when measuring signals that change over time, the bar graph can be easier to understand than changing numbers.
AM-1060 Digital Multimeter Features and Benefits
Large LCD display with bar graph indication and frequency measurement path
4000 counts A/D, high resolution
multi function measurement: DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Temperature, Diode, Continuity beeper
10 MOhm input impedance for voltage circuit
Auto range with manual range selection
VAHz button, when execute the ACV, ACA function also can measure the frequency of signal
"Absolute measurement error" service allows you to estimate the measurement accuracy considering uncertainty (error) in the absolute value. It's important if you take measurements at the range edge when the error value contributes to the value displayed on the device screen.
To get the value range it'd be enough to enter the estimate of the value under measurement into Value input field and to see the range of possible values taking all of the standardized errors into consideration.
Note: a point is used as a separator of the integer and fractional part.
DC Voltage
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
400 mV
0.1 mV
±(0.5%+2 digits)
±2.1995 mV
mV
4 V
0.001 V
±(0.8%+1 digits)
±0.032992 V
V
40 V
0.01 V
±(0.8%+1 digits)
±0.32992 V
V
400 V
0.1 V
±(0.8%+1 digits)
±3.2992 V
V
1000 V
1 V
±(0.8%+1 digits)
±8.992 V
V
AC Voltage
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
400 mV
0.1 mV
±(1.0%+2 digits)
±4.199 mV
mV
4 V
0.001 V
±(1.0%+2 digits)
±0.04199 V
V
40 V
0.01 V
±(1.0%+2 digits)
±0.4199 V
V
400 V
0.1 V
±(1.0%+2 digits)
±4.199 V
V
1000 V
1 V
±(1.0%+2 digits)
±11.99 V
V
DC Current
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
400 µA
0.1 µA
±(1.5%+2 digits)
±6.1985 µA
µA
4000 µA
1 µA
±(1.5%+2 digits)
±61.985 µA
µA
40 mA
0.01 mA
±(1.0%+2 digits)
±0.4199 mA
mA
400 mA
0.1 mA
±(1.5%+2 digits)
±6.1985 mA
mA
10 A
0.01 A
±(1.0%+2 digits)
±0.1199 A
A
AC Current
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
400 µA
0.1 µA
±(1.5%+2 digits)
±6.1985 µA
µA
4000 µA
1 µA
±(1.5%+2 digits)
±61.985 µA
µA
40 mA
0.01 mA
±(1.0%+2 digits)
±0.4199 mA
mA
400 mA
0.1 mA
±(1.5%+2 digits)
±6.1985 mA
mA
10 A
0.01 A
±(1.0%+2 digits)
±0.1199 A
A
Frequency
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
4 kHz
0.001 kHz
±(0.5%+2 digits)
±0.021995 kHz
kHz
40 kHz
0.01 kHz
±(0.5%+2 digits)
±0.21995 kHz
kHz
400 kHz
0.1 kHz
±(0.5%+2 digits)
±2.1995 kHz
kHz
4 MHz
1 kHz
±(0.5%+2 digits)
±0.021995 MHz
MHz
40 MHz
10 kHz
±(0.5%+2 digits)
±0.21995 MHz
MHz
Resistance
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
400 Ω
0.1 Ω
±(1.0%+2 digits)
±4.199 Ω
Ω
4 kΩ
1 Ω
±(1.5%+2 digits)
±0.061985 kΩ
kΩ
40 kΩ
10 Ω
±(1.5%+2 digits)
±0.61985 kΩ
kΩ
400 kΩ
100 Ω
±(1.5%+2 digits)
±6.1985 kΩ
kΩ
4 MΩ
1 kΩ
±(1.5%+2 digits)
±0.061985 MΩ
MΩ
40 MΩ
10 kΩ
±(3.0%+5 digits)
±1.2497 MΩ
MΩ
Capacitance
Range
Resolution
Accuracy
Absolute error
Value-error
Value
Value+error
4 nF
0.001 nF
±(3.0%+1 digits)
±0.12097 nF
nF
40 nF
0.01 nF
±(3.0%+1 digits)
±1.2097 nF
nF
400 nF
0.1 nF
±(3.0%+1 digits)
±12.097 nF
nF
4 µF
0.001 µF
±(3.0%+1 digits)
±0.12097 µF
µF
40 µF
0.01 µF
±(3.0%+1 digits)
±1.2097 µF
µF
400 µF
0.1 µF
±(3.0%+1 digits)
±12.097 µF
µF
4 mF
0.001 mF
±(4.0%+1 digits)
±0.16096 mF
mF
40 mF
0.01 mF
±(12.0%+1 digits)
±4.8088 mF
mF
Specifications
Function
Range
Resolution
Accuracy
DC Voltage
400mV
0.1mV
±(0.5%reading+2digits)
4V
0.001V
±(0.8%reading+1digits)
40V
0.01V
400V
0.1V
1000V
1V
AC Voltage (50/60Hz)
400mV
0.1mV
±(1.0%reading+2digits)
4V
0.001V
40V
0.01V
400V
0.1V
1000V
1V
DC Current
400µA
0.1µA
±(1.5%reading+2digits)
4000µA
1µA
40mA
0.01mA
±(1.0%reading+2digits)
400mA
0.1mA
±(1.5%reading+2digits)
10A
0.01A
±(1.0%reading+2digits)
AC Current (50/60Hz)
400µA
0.1µA
±(1.5%reading+2digits)
4000µA
1µA
40mA
0.01mA
±(1.0%reading+2digits)
400mA
0.1mA
±(1.5%reading+2digits)
10A
0.01A
±(1.0%reading+2digits)
Resistance
400Ω
0.1Ω
±(1.0%reading+2digits)
4kΩ
1Ω
±(1.5%reading+2digits)
40kΩ
10Ω
400kΩ
100Ω
4MΩ
1kΩ
40MΩ
10kΩ
±(3.0%reading+5digits)
Continuity buzzer: <20Ω ; Max Voltage 500V (DC) / 250V (AC rms)
Capacitance
4nF
0.001nF
±(3.0%reading+1digits)
40nF
0.01nF
400nF
0.1nF
4µF
0.001µF
40µF
0.01µF
400µF
0.1µF
4mF
0.001mF
±(4.0%reading+1digits)
40mF
0.01mF
±(12.0%reading+1digits)
Frequency (response 1.5V...5V)
4kHz
0.001kHz
±(0.5%reading+2digits)
40kHz
0.01kHz
400kHz
0.1kHz
4MHz
1kHz
40MHz
10kHz
Temperature
(K-type)
-20°C...300°C
1°C
±(1.0%reading+2digits)
301°C...750°C
1°C
±(3.0%reading)
General specifications
Display: 2.6x2in / 65x48mm large LCD (4000 counts) display with bar graph indication and frequency measurement path
Range selection: Auto range with manual range selecting
Data hold: To freeze the display reading on the LCD display
Memory recall: Records Maximum & Minimum readings with recall
Peak value: To measure the signal peak value (>1ms)
Relative measurement: To offset the measurement value
Operating temperature: 0°C to 50°C (32°F to 122°F)
Operating humidity: Max. 80%RH.
Power supply: 1.5V battery x 2 PCs UM-4/AAA/Micro/R03 type
Power consumption: Approx. DC 1.7mA
Dimensions: 7.3x3.5x1.6in / 185x88x40mm
Weight: 0.77lb / 350g
Included accessories
Red and Black Test Lead
0.5 Amp Spare Fuse
User Manual
Optional accessories
Full line adapters: ACA/DCA current adapter, adapter, Tachometer adapter, Humidity adapter, Pressure adapter, Light adapter, EMF adapter, Sound level adapter, High voltage probe
Soft carrying case
Temperature probe
DMM basic measurement functions
As an example: oscilloscope diagnostic board AKTAKOM AEE-1017-V1 testing modes are given.
AC/DC Voltage (parallel connection to the circuit) & Current (serial! connection to the break in circuit)
e.g.: sine output (3V/5kHz)
AC Voltage Line Frequency ("Hz" button)
e.g.: "FM" output (5kHz)
Resistance measurement
e.g.: 4.5 kOhm resistor
Capacitance
e.g.: SMD capacitor
Frequency (logic)
e.g.: Counter impulse frequency
Continuity (sound buzzer)
e.g.: between different "ground" points of the circuit
Does AKTAKOM AM-1060 multimeter have auto power off function?
Yes, it does. There is Auto Power Off function in AM-1060: the device power automatically goes off if you do not use the device within 15 minutes. 30 seconds before the device powers off it will make 3 short sound signals and before powering off – one more long signal. To start the operation again press any button or use the rotary switch.
Front panel covers LCD, button board, rotary function switch gear and main plated circuit board:
*Rubber strip between the back and front chassis covers protects from water and dust.
Protective fuses are mounted near the inputs and sound buzzer is placed behind the LCD.
*There is also an extra fuse fixed at the buttom (for several models) Up
How to replace or install the batteries in AM-1060?
When the batteries become exhausted or drop below the operating voltage, “BAT” indicator will appear in the LCD display. In this case the battery should be replaced, however in-spec. measurements may still be made for several hours after "Low battery indicator" appears before the instrument become inaccurate.
WARNING! To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery cover.
"DC 1.5V" type AAA (e.g. AM-1060)
1. Open the battery cover by loosing the screws with the cross-point screwdriver
2. Carefully pull out the buttery carrier and take off the old batteries
3. Plug the new batteries of the proper type in the holder and put it back
4.Close the battery cover and reinstate the cover
After completion make sure you don’t have any spare parts
If you do find spare parts, you must start all over
Designing Off Delay Timer Switch for Water Pump Control
Electrical Engineer Shows You How to Fix Your Pool Electrical Supply
LED Repair Tutorial Part 5
How to Use a Digital Multimeter to Test LED Chips
LED Repair Tutorial Part 4
Fixing LED Light Fixture Part 3: Unforeseen causes of broken LED lights
LED Light Driver Repair and Redesign using AKTAKOM AM-1060 DMM
Useful Features of the AKTAKOM AM-1060 Multimeter
How to fix LED light fixture using AKTAKOM AM-1060 DMM, ASE-1209 Soldering Tweezers and APS-7306 Power Supply
How to Use AM-1060 Multifunctional Multimeter
AKTAKOM AM-1060 ofrece multiples funciones de medición como DCV, ACV, DCA, ACA, resistencia, capacitancia, frecuencia, temperatura, testeo de diodos y zumbador de continuidad.
Características
Cumple con la norma IEC 1010 CAT III 1000V.
Monitor digital LCD con indicador gráfico de barras.
Detección de picos con Máximo y mínimo, alternos y retención de datos.
Auto rango con selección manual de los mismos.
Termometro °C/°F
Botón VAHz, cuando se ejecuta la función de ACV, ACA y también puede medir la frecuencia de la señal.
Alta resolución con 4000 cuentas A/D.
Fusible incorporado para los rangos de corriente 10 A, mA, uA.
Impedancia de entrada de 10 M Ohm para el circuito de tensión.